首页 > 电池测试 > LBTS-Cell High Volume
Video
Arbin BT LBTS-Cell-High-Volume
Arbin BT LBTS High Volume Left-min
Arbin BT LBTS High Volume Right-min
Arbin-BT-LBTS-High-Volume-Straight
previous arrow
next arrow
Video
播放
Arbin BT LBTS-Cell-High-Volume
Arbin BT LBTS High Volume Left-min
Arbin BT LBTS High Volume Right-min
Arbin-BT-LBTS-High-Volume-Straight
previous arrow
next arrow

LBTS-Cell High Volume

The perfect solution for high-volume testing. Ideal for incoming quality control and large-scale testing.

Highlights

  • Ideal for incoming cell quality control and validation​
  • 2 Current Ranges per Channel allows double channel density​
  • Built-in thermistor PT100 input per channel available​
  • Built-in DCIM Measurement feature​
  • Built-in Self Discharge Current Measurement feature​
  • <100ppm Measurement Precision​
  • 24-Bit Voltage & Current Measurement Resolution​
  • Bipolar circuitry = No "switching time" and cross-zero linear​
  • EIS measurement up to 100kHz available
  • 1A or 10A per Channel​

系统 规格

Battery Testing - Cell
LBTS-Cell High Volume
硬件设施
频道数
192
256
Voltage Ranges
0V - 5V
(-5V) - 5V
Current Ranges
10A
1mA
1A
1mA
测量分辨率
24bit
Measurement&Control Precision
+/-0.01% FSR
Measurement&Control Accuracy
+/-0.02% FSR
输入阻抗
100G Ohm
Current Rise Time (10%-90%)
≤150us*
General
Data Acquisition Rate
Regular mode: up to 1kHz, Burst Mode: up to 16kHz
机箱尺寸(宽x深x高)
25"x45"x71"
0 ~ 30C
输入电压
208V3P/380V3P/480V3P

电池测试 综合解决方案

CC - Constant Current

The Constant Current (CC) control mode is designed to deliver a steady current to the battery based on the specified value. This mode is crucial in scenarios where maintaining a steady current is necessary, such as during charge or discharge cycles.

The polarity of the current determines the operation mode: a positive current corresponds to charging, while a negative current corresponds to discharging.

ARBIN-CC - Constant Current
ARBIN-CV - Constant Voltage

CV - Constant Voltage

The Constant Voltage (CV) control mode regulates the voltage output to the battery according to the set value. This mode is essential for applications where voltage stability is critical, ensuring the battery operates within safe voltage limits.

The CV mode is particularly useful in the latter stages of charging, where it ensures that the battery reaches and maintains the desired voltage level without exceeding it, thus protecting the battery's longevity and performance.

CCCV - Constant Current & Constant Voltage

The Constant Current-Constant Voltage (CCCV) control mode facilitates an integrated charging process, where the battery is initially charged under a Constant Current (CC) regime until a predefined voltage threshold is reached. Upon reaching this threshold, the system seamlessly transitions to a Constant Voltage (CV) mode, where the current gradually decreases as the battery approaches full charge.

You can specify both the current (CC) and voltage (CV) parameters in a single step. This mode ensures both efficient charging and the prevention of overcharging, with termination criteria based on either time or a minimum current threshold.

ARBIN-CCCV - Constant Current & Constant Voltage

Advanced Application Features

Centralized Infrastructure

Unified platform for synchronized management, data storage, and control of multiple battery testing stations.

Distributed Infrastructure

Distributed testing infrastructure for scalable and flexible battery testing.

Standalone Station

Independent setup for localized battery testing with integrated data management and analysis capabilities.

SQL Databases

Reliable and scalable storage solution for managing and querying battery testing data.

APIs integration

Flexible APIs for easy integration and automation of battery testing processes across platforms.

Cloud Integration

Effortless connectivity to cloud platforms for secure data storage, backup, and real-time access.

Software Testing 应用

MITS 11

You will experience seamless integration across web, desktop, and API interfaces with our next-gen application. Harnessing the power of cloud database integration and innovative data streaming, our platform delivers unmatched efficiency and reliability. Enjoy scalable solutions with integrated sub-products designed to elevate your operations.

ARBIN-MITS 11
ARBIN-Standalone Testing Setup

Standalone Testing Setup

The standalone testing setup offers a self-sufficient solution for battery evaluations. Equipped with all necessary hardware and software, it ensures accurate data collection and analysis, making it ideal for labs and field environments without relying on external systems.

Decentralized Testing Infrastructure

The decentralized testing infrastructure provides a scalable solution for battery testing across multiple locations. Each site operates independently yet remains interconnected, allowing for robust data synchronization, load balancing, and enhanced redundancy to maximize efficiency and reliability.

ARBIN-Decentralized Testing Infrastructure
ARBIN-Testing as a service [TAAS]

Testing as a service [TAAS]

Testing as a Service (TaaS) delivers an all-inclusive solution for battery evaluation and data analysis. Leveraging advanced infrastructure, clients can access top-tier testing capabilities on demand, ensuring accurate results and streamlined processes without the need for dedicated in-house resources.

Related Battery Testing Solutions

RBT-Cell

High current cell testing solutions utilizing Arbin's regenerative technology for efficient and reliable testing.

LBTS-Cell

Arbin's next generation of high-precision solutions for a full range of cell testing applications.

LBTS-Cell High Volume

The perfect solution for high-volume testing. Ideal for incoming quality control and large-scale testing.

LBTS-Module

The LBTS-Module is equipped with Arbin's advanced technology, high precision, suitable for all purpose module testing. ​

RBT-Module

The RBT system ensures high power density and efficiency, while its regenerative circuitry returns power to the grid, making it economical for testing.​

RBT-High Power​

Arbin's highest power tester, offering superior energy efficiency, is ideal for heavy-duty testing.​

滚动到顶部